Siglent SHS1102 Dual-Channel, 100MHz Bandwidth
https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhsj-qTRPH9KcuebwhkzAoTcWXh1jhOLIyE5B7mz4TGh1yELH2Q1zYWC2gZjIXPS1bGQ8L4lr_zlv-meaEef3cQaLyHrnpkFfGaBXByvz5lzvaaG2a2Fa1HVyuZZRrOy52okrvsiytZoLsk/s72-c/siglent+shs1102.jpg
Siglent SHS1102 Handheld Oscilloscope (Dual-Channel, 100MHz Bandwidth)
- 100MHz bandwidth
- Built-in multimeter
- Dual-channel
Description
Siglent SHS1102 Handheld Oscilloscope (Bandwidth 100MHz) Details
The Siglent SHS1102 is a dual-channel digital oscilloscope with a large 5.7 inch colour screen and is portable enough to be carried around between different testing scenarios.
It is suitable for use in a wide range of different applications including power electronics testing (switching mode power supplies, inverter, converters and lighting), wind power, PV power and other new energy equipment tests, automotive electronic testing, electrical vehicle testing, industrial power system testing, field testing, educational applications and more.
To help enhance testing and safety the SHS1000 series comes with built-in IsolatedChannel technology, a patented unique technique used by Siglent to provide isolation from ground and isolation between channels.
This particular tester features 100MHz bandwidth, real-time sample rate of 1GSa/s, equivalent sampling rate of 50GSa/s and 2Mpts memory depth.
Also integrated into the SHS1102 is a fully-functional multimeter that is capable of measuring DC/AC voltage, DC/AC current, resistance, capacitance, diode and continuity.
Siglent SHS1102 Handheld Oscilloscope Key Features
- 2-channel device
- Includes IsolatedChannel technology that isolates ground and between channels
- 5.7 inch colour LCD display
- 100MHz bandwidth
- 6000 count multimeter measures DC/AC Voltage, DC/AC current, Resistance, Diode, Capacitance and Continuity
- Includes Trendplot, Meter Trendplot and Scope recording functions
- Automatic and manual trigger modes
- Trigger types: Edge, Pulse, Video, Slope and Alternative
- 32 automatic waveform measurements, 3 cursor measure modes
- Digital filter functions: high pass, band pass, band limit
- Mathematical functions: +, -, x, ÷ and FFT
- Multiple language user interface
- USB device and USB host with PC communication
- Rechargeable battery
- Ideal for multiple applications including power electronics, industrial power systems, field testing and more
Full List of Products Included
- Siglent SHS1102 Handheld Digital Oscilloscope
- 9V, 3A power adapter
- Two oscilloscope probes: 1 x CAT II 1000V and 1 x CAT III 600V (100MHz)
- Two test leads for multimeter measurements
- USB data transmitting cable
- User manual
- Service warranty card
- CD including Easyscope software
Technical Specification
ype | SHS1062 | SHS1102 |
Bandwidth | 60MHz | 100MHz |
Rise Time | ≤5.8ns | ≤3.5ns |
Real Time Sampling Rate | Single Channel: 1GSa/s, Double Channels: 500MSa/s |
Single Channel: 1GSa/s, Double Channels: 500MSa/s |
Equivalent Sampling Rate | 50GSa/s | 50GSa/s |
Memory Depth | 2Mpts | 2Mpts |
Time Base Range | 5 ns/ div – 50s/ div | 2.5ns/ div – 50s/ div |
Scan Range | 100ms/ div ~ 50s/ div | 100ms/ div ~ 50s/ div |
Vertical Sensitivity | 5mV/div – 100V/div(1-2-5 order) | 5mV/div – 100V/div(1-2-5 order) |
Vertical Resolution | 8 bits | 8 bits |
Trigger Types | Edge, Pulse, Video, Slope, Alternative | Edge, Pulse, Video, Slope, Alternative |
Frequency Counter | 6 bits | 6 bits |
Connection | USB Device, USB Host | USB Device, USB Host |
Math | +, -, * , /, FFT | +, -, * , /, FFT |
Oscilloscope Trend Plot | 800K points | |
Meter | ||
Maximum Resolution | 6000 | |
DC Voltage | 60mV 600mV—1000V |
(±1%±15digit) (±1%±5digit) |
AC Voltage | 60mV 600mV—750V |
(±1%±15digit) (±1%±5digit) |
DC Current | 60.00mA—600mA 6A—10A |
(±1%±5digit) (±1.5%±5digit) |
AC Current | 60.00mA—600mA 6A—10A |
(±1%±5digit) (±1.5%±5digit) |
Resistance | 600Ω—60MΩ | (±1%±5digit) |
Capacitance | 40nF 400nF--400uF |
(±3%±10digit) (±4%±5digit) |
Diode | 0—2V | |
Continuity | <50Ω Buzzer sounds | |
Multimeter Trend Plot | 1.2M points |
channels from earth ground, between two channels references |
Overvoltage Category | Maximum Voltage |
CAT I&CAT II | 1000 Vrms | |
CAT Ⅲ | 600 Vrms | |
between Multimeter input reference and the ground |
Overvoltage Category | Maximum Voltage |
CAT I&CAT II | 600 Vrms | |
CAT Ⅲ | 300 Vrms | |
Max. input Voltage for BNC | Overvoltage Category | Maximum Voltage |
1x CAT I&CAT II | 300 Vrms | |
1X CAT Ⅲ | 150 Vrms | |
10x CAT I&CAT II | 1000 Vrms | |
10X CAT Ⅲ | 600 Vrms | |
Max. input Voltage for Multimeter input port |
Voltage port | DC 1000V, AC 750V |
Current port(mA) | AC 250V/600mA | |
Current port(A) | AC 250V/10A | |
Single Channel Common Mode Rejection, typical |
>1000:1 50MHz | |
Channel-to-Channel Isolation |
>35 dB |